Edwards Signaling 2414 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Wykrywacze dymu Edwards Signaling 2414. Edwards Signaling 2414 Service manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 87
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
QUAKER BRIDGE MALL
LAWRENCEVILLE, NJ
FOOD COURT AREA
FIRE ALARM SYSTEM
EQUIPMENT SUBMITTAL
SUBMITTAL PREPARED BY
SYSTEMS SALES CORPORATION
1345 CAMPUS PARKWAY
MONMOUTH SHORES CORPORATE PARK
NEPTUNE, NJ 07753-6815
(732) 751-0600
www.sscnj.com
NEW JERSEY STATE FIRE ALARM PERMIT NO. P00525
ELECTRIC CONTRACTOR
ARMOUR & SONS
LANGHORNE, PA
SSC Project No. 40689
7/5/12
Przeglądanie stron 0
1 2 3 4 5 6 ... 86 87

Podsumowanie treści

Strona 1 - EQUIPMENT SUBMITTAL

QUAKER BRIDGE MALL LAWRENCEVILLE, NJ FOOD COURT AREA FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL SUBMITTAL PREPARED BY SYSTEMS

Strona 2

Data Sheet 85010-0059 Issue 10.1Not to be used for installation purposes. Page 2 of 4Power Supply Rules1. Each battery set needs one charger, either

Strona 3

Data Sheet 85010-0059 Issue 10.1Not to be used for installation purposes. Page 3 of 4PrimaryPowerSupplyBoosterPowerSupply24Vdc *2 x 3.5A24Vdc *2 x 3.5

Strona 4

Data Sheet 85010-0059 Issue 10.1Not to be used for installation purposes. Page 4 of 4GESecurityU.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 5

Strona 5 - Cabinets and

Data Sheet 85010-0133 Issue 5.1Not to be used for installation purposes. Page 1 of 4GESecurityEST Life Safety & CommunicationsEST3 Multiplexed Fir

Strona 6

Data Sheet 85010-0133 Issue 5.1Not to be used for installation purposes. Page 2 of 4Installation and MountingPowerSupplyPowerSupplyJ8J9J10J11J8J9J10J1

Strona 7 - BC-1 Dimensions

Data Sheet 85010-0133 Issue 5.1Not to be used for installation purposes. Page 3 of 4CENTRALPROCESSINGUNIT MODULE11 112 214 413 315 516 617 718 819 920

Strona 8 - 85010-0067

Data Sheet 85010-0133 Issue 5.1Not to be used for installation purposes. Page 4 of 4GESecurityU.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 51

Strona 9 - EST3 Power Supplies

Data Sheet 85010-0107 Issue 5.1Not to be used for installation purposes. Page 1 of 4GESecurityEST Life Safety & CommunicationsEST3 Multiplexed Fir

Strona 10 - Installation and Mounting

Data Sheet 85010-0107 Issue 5.1Not to be used for installation purposes. Page 2 of 4Application Two versions of the Modcom are available:3-MODCOM - Ha

Strona 11 - Specifications

Data Sheet 85010-0107 Issue 5.1Not to be used for installation purposes. Page 3 of 4Ordering InformationSpecificationsAgency Listings UL, FCC Part 68 /

Strona 13 - Processor Unit

Data Sheet 85010-0107 Issue 5.1Not to be used for installation purposes. Page 4 of 4GESecurityU.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 51

Strona 14

Data Sheet 85010-0129 Issue 4.1Not to be used for installation purposes. Page 1 of 4GESecurityEST Life Safety & Communications EST3 Multiplexed F

Strona 15

Data Sheet 85010-0129 Issue 4.1Not to be used for installation purposes. Page 2 of 4ApplicationUp to 125 detectors and 125 modules are supported over

Strona 16

Data Sheet 85010-0129 Issue 4.1Not to be used for installation purposes. Page 3 of 4for maintenance and trouble conditions. Each smoke detector contai

Strona 17 - Communicator

Data Sheet 85010-0129 Issue 4.1Not to be used for installation purposes. Page 4 of 4GESecurityU.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 51

Strona 18

Data Sheet 85010-0057 Issue 8Not to be used for installation purposes. Page 1 of 4GESecurityEST Life Safety & CommunicationsEST3 Multiplexed Fire

Strona 19 - Ordering Information

Data Sheet 85010-0057 Issue 8Not to be used for installation purposes. Page 2 of 4ApplicationEST3 zoned amplifier configurations offer improved system s

Strona 20

Data Sheet 85010-0057 Issue 8Not to be used for installation purposes. Page 3 of 4Specifications3-ZA20A 3-ZA20B 3-ZA40A 3-ZA40B 3-ZA95Agency Listing UL

Strona 21 - Controller Modules

U.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 519 376 7258AsiaT 852 2907 8108F 852 2142 5063AustraliaT +61 3 9239 1200F +61 3 9239 1299EuropeT

Strona 22

Data Sheet 85010-0055 Issue 4Not to be used for installation purposes. Page 1 of 4GESecurityEST Fire & Life SafetyEST3 Multiplexed Fire Alarm Syst

Strona 24

Data Sheet 85010-0055 Issue 4Not to be used for installation purposes. Page 2 of 4Application NotesControl Display Modules come in a variety of types

Strona 25 - Amplifiers

Data Sheet 85010-0055 Issue 4Not to be used for installation purposes. Page 3 of 4Technical SpecificationsEngineering SpecificationThe Life Safety syste

Strona 26

U.S.T 888-378-2329F 866-503-3996CanadaT 519 376 2430F 519 376 7258AsiaT 852 2907 8108F 852 2142 5063AustraliaT 61 3 9259 4700F 61 3 9259 4799EuropeT 3

Strona 27

Page 1 of 4 D A T A S H E E T 85010-0063 Not to be used for installation purposes. Issue 11 EST Catalog u EST3 Life Safety Platform06-21-1006

Strona 28

Page 2 of 4 D A T A S H E E T 85010-0063 Not to be used for installation purposes. Issue 11 ApplicationEST3 audio is accomplished by selectin

Strona 29 - Control Display

Page 3 of 4 D A T A S H E E T 85010-0063 Not to be used for installation purposes. Issue 11 Dashed Wires Requiredfor Class 'A' Wiri

Strona 30 - Application Notes

Page 4 of 4 D A T A S H E E T 85010-0063 Not to be used for installation purposes. Issue 11 06-21-1006-21-10Detection & alarm since 1872U

Strona 31 - Technical Specifications

Page 1 of 4 D A T A S H E E T 85010-0069 Not to be used for installation purposes. Issue 10 EST Catalog u EST3 Life Safety Platform06-21-10Ap

Strona 32

Page 2 of 4 D A T A S H E E T 85010-0069 Not to be used for installation purposes. Issue 10 TX RXTXRXTX RXTXRXTX RXTXRXTX RXTXRXNOTES:1. All

Strona 33 - Telephone

Page 3 of 4 D A T A S H E E T 85010-0069 Not to be used for installation purposes. Issue 10 DimensionsSemiflush10.1 in. (25.7 cm)2.75 in. (7.

Strona 35 - Mass Notification

Page 4 of 4 D A T A S H E E T 85010-0069 Not to be used for installation purposes. Issue 10 06-21-10Detection & alarm since 1872U.S.T 888

Strona 36

NFPA®Made In U.S.A.ISO9001REGISTEREDBCABattery Cabinet AccessoryThe BCA Battery Cabinet Accessory is designed for the pro-fessional installation of s

Strona 37 - Annunciators

Ordering Information:Part # DescriptionYI0428 BCA Battery Cabinet, RedYI0429 BCA Battery Cabinet, BlackSpecifi cations:The BCA Battery Cabinet A

Strona 38 - 85010-0069

Rechargeable Sealed Lead-Acid Battery PERFORMANCE SPECIFICATIONSNominal Vol

Strona 39

CHARGINGCycle Applications: Limit initial current to 15A. Charge until batteryvoltage (under charge) reaches 14.40 to 14.70 volts at 68oF (20oC).Hold

Strona 40

Page 1 of 4 D A T A S H E E T 85005-0125 Not to be used for installation purposes. Issue 4 EST Catalog u Power Supplies and Accessories06-21-

Strona 41 - Standard Features:

Page 2 of 4 D A T A S H E E T 85005-0125 Not to be used for installation purposes. Issue 4 ApplicationThe BPS provides additional power and c

Strona 42 - Specifi cations:

Page 3 of 4 D A T A S H E E T 85005-0125 Not to be used for installation purposes. Issue 4 Typical WiringSingle or cascaded booster anywhere

Strona 43 - 12 Volt 55 Amp. Hrs

Page 4 of 4 D A T A S H E E T 85005-0125 Not to be used for installation purposes. Issue 4 06-23-1006-23-10Detection & alarm since 1872U.

Strona 44 - E-mail: [email protected]

Page 1 of 4 D A T A S H E E T 85001-0543 Not to be used for installation purposes. Issue 3 EST Catalog u Intelligent Input-Output06-21-10Over

Strona 45 - Power Supplies

Page 1 of 4 D A T A S H E E T 85010-0067 Not to be used for installation purposes. Issue 10 EST Catalog u EST3 Life Safety Platform06-21-10St

Strona 46 - Wire routing

Page 2 of 4 D A T A S H E E T 85001-0543 Not to be used for installation purposes. Issue 3 ApplicationThe SIGA-CC1S mounts to a standard Nort

Strona 47 - 85005-0125

Page 3 of 4 D A T A S H E E T 85001-0543 Not to be used for installation purposes. Issue 3 Typical WiringSIGA-CC1S (Standard Mount) SIGA-MCC1

Strona 48

Page 4 of 4 D A T A S H E E T 85001-0543 Not to be used for installation purposes. Issue 3 06-21-10Detection & alarm since 1872U.S.T 888-

Strona 49 - Output Module

Rechargeable Sealed Lead-Acid Battery PERFORMANCE SPECIFICATIONSNominal Vol

Strona 50 - 85001-0543

1201008060402000 200 400 600 800 1000 1200Number of CyclesCHARGINGCycle Applications: Limit initial current to 2.1A.

Strona 51

01-25-11Page 1 of 4 D A T A S H E E T 85001-0619 Not to be used for installation purposes. Issue 1EST Catalog  Intelligent Initiating DevicesIn

Strona 52

Page 2 of 4 D A T A S H E E T 85001-0619 Not to be used for installation purposes. Issue 1ApplicationSmoke detectionThe SIGA2-PS detects extreme

Strona 53 - 12 Volt 7.0 Amp. Hrs

Page 3 of 4 D A T A S H E E T 85001-0619 Not to be used for installation purposes. Issue 1Typical WiringThe detector mounting bases accept #18 A

Strona 54

01-25-11Page 4 of 4 D A T A S H E E T 85001-0619 Not to be used for installation purposes. Issue 1Detection & alarm since 1872U.S.T 888 378

Strona 55 - CO Sensor

01-25-11Page 1 of 4 D A T A S H E E T 85001-0620 Not to be used for installation purposes. Issue 1EST Catalog  Intelligent Initiating DevicesOv

Strona 56 - Accessories

Page 2 of 4 D A T A S H E E T 85010-0067 Not to be used for installation purposes. Issue 10 Installation and MountingLobby Enclosure 3-cab5B

Strona 57

Page 2 of 4 D A T A S H E E T 85001-0620 Not to be used for installation purposes. Issue 1ApplicationHeat detectionSIGA2-HRS rate-of-rise heat d

Strona 58 - Warnings & Cautions

Page 3 of 4 D A T A S H E E T 85001-0620 Not to be used for installation purposes. Issue 1Typical WiringThe detector mounting bases accept #18 A

Strona 59 - CO Sensors

01-25-11Page 4 of 4 D A T A S H E E T 85001-0620 Not to be used for installation purposes. Issue 1Detection & alarm since 1872U.S.T 888 378

Strona 60 - 85001-0620

Page 1 of 4 D A T A S H E E T 85001-0584 Not to be used for installation purposes. Issue 5 EST Catalog u Intelligent Initiating06-21-10Overvi

Strona 61

Page 2 of 4 D A T A S H E E T 85001-0584 Not to be used for installation purposes. Issue 5 ApplicationSuperDuct detectors are ideally suited

Strona 62

Page 3 of 4 D A T A S H E E T 85001-0584 Not to be used for installation purposes. Issue 5 AssemblyHVAC ductAirflowSamplingtubeDetector#10 sh

Strona 63 - Smoke Detector

Page 4 of 4 D A T A S H E E T 85001-0584 Not to be used for installation purposes. Issue 5 06-21-10Detection & alarm since 1872U.S.T 888-

Strona 64

Page 1 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 EST Catalog u Intelligent Input/Output06-21-10Ov

Strona 65 - Mounting

Page 2 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 InstallationSIGA-CR and SIGA-CRR: modules mount

Strona 66

Page 3 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 SIGA-CR Control RelayTypical Wiring Modules wi

Strona 67 - Control Relay

Page 3 of 4 D A T A S H E E T 85010-0067 Not to be used for installation purposes. Issue 10 Ordering InformationCatalog NumberDescriptionEqui

Strona 68

Page 4 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 AB4GAudible BaseAB4GAudible BaseOptional CRfor d

Strona 69

Page 5 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 SpecificationsOrdering InformationCatalog Number

Strona 70

Page 6 of 6 D A T A S H E E T 85001-0239 Not to be used for installation purposes. Issue 7.2 06-21-10Detection & alarm since 1872U.S.T 88

Strona 71

Page 1 of 4 D A T A S H E E T 85001-0241 Not to be used for installation purposes. Issue 7.1 EST Catalog u Intelligent Input-Output06-21-10Ov

Strona 72 - Signature Series Overview

Page 2 of 4 D A T A S H E E T 85001-0241 Not to be used for installation purposes. Issue 7.1 InstallationSIGA-CT1 and SIGA-CT2: modules mount

Strona 73 - Input Modules

Page 3 of 4 D A T A S H E E T 85001-0241 Not to be used for installation purposes. Issue 7.1 Typical Wiring Modules will accept #18 AWG (0.

Strona 74

Page 4 of 4 D A T A S H E E T 85001-0241 Not to be used for installation purposes. Issue 7.1 06-21-10Detection & alarm since 1872U.S.T 88

Strona 75

RIC-1, RIC-2 Series RelayMulti-Voltage Relay Module©Space Age Electronics, Inc. 2003ED0400 LT10280 Rev. A Pg. 1/1The RIC-1 and RIC-

Strona 76

Page 1 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 EST Catalog u Strobes, Horns, Bells, Chimes06-21-

Strona 77 - RIC-1, RIC-2 Series Relay

Page 2 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 ApplicationGenesis strobes are UL 1971-listed for

Strona 78 - Horns and Strobes

Page 4 of 4 D A T A S H E E T 85010-0067 Not to be used for installation purposes. Issue 10 06-21-10Detection & alarm since 1872U.S.T 888

Strona 79

Page 3 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 Notes and Comments1. Current values are shown in

Strona 80 - Current Draw

Page 4 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 SpecificationsdBA outputNotes1. All values shown

Strona 81 - Average Sound Output (dBA)

Page 5 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 Ordering InformationModel Housing Marking Lens S

Strona 82 - Information

Page 6 of 6 D A T A S H E E T 85001-0573 Not to be used for installation purposes. Issue 10 06-21-10Detection & alarm since 1872U.S.T 888

Strona 83 - 85001-0573

Page 1 of 4 D A T A S H E E T 85001-0549 Not to be used for installation purposes. Issue 9 EST Catalog u Speakers, Telephones06-21-10Standard

Strona 84 - Genesis Speakers

Page 2 of 4 D A T A S H E E T 85001-0549 Not to be used for installation purposes. Issue 9 Speaker ApplicationThe suggested sound pressure le

Strona 85 - Strobe Application

Page 3 of 4 D A T A S H E E T 85001-0549 Not to be used for installation purposes. Issue 9 SPKRS+CS-Speaker-Strobe WiringPolarity shown inala

Strona 86 - Light output

Page 4 of 4 D A T A S H E E T 85001-0549 Not to be used for installation purposes. Issue 9 06-21-10Detection & alarm since 1872U.S.T 888-

Strona 87

Data Sheet 85010-0059 Issue 10.1Not to be used for installation purposes. Page 1 of 4GESecurityEST Life Safety & CommunicationsEST3 Multiplexed Fi

Komentarze do niniejszej Instrukcji

Brak uwag